10/27/2022 | COT - LCBU - Framing | Not Ready | ||
04/20/2023 | COT - LCBU - Framing | Re-inspection required | 4/20/23: fire block at 10 feet vertical at stairs, block base of landing, block register box, loose wire in 2nd floor hall, fire block 2nd floor west wall chase every 10 feet horizontally, install metal collar at B-vent at 2nd floor top plate, remove abandoned flex duct in attic. | |
04/26/2023 | COT - LCBU - Framing | Passed | 4-26-23: Fire blocking has been installed at stairs, landing, and register. Loose wire has been attached to stud on second floor. B-vent has been installed on second floor top plate. All abandoned flex duct has been removed from attic space. |