Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - RSEL - Electrical Final |
|
Not Ready |
|
| 03/16/2023 |
COT - RSEL - Electrical Final |
|
Not Ready |
House and side yard locked, no access |
| 06/28/2024 |
COT - RSEL - Electrical Final |
|
Re-inspection required |
6/28/24: hammer arrestors needed at refrigerator and washer. GFCI protected receptacles are needed for dishwasher. Arc fault protected breakers needed for living spaces. And anti tip needs to be installed for stove. |
| 07/09/2024 |
COT - RSEL - Electrical Final |
|
Passed |
|