Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - LCPL - Plumbing Intermediate
Permit Number - T22CM04628
Inspection Description - COT - LCPL - Plumbing Intermediate
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | COT - LCPL - Plumbing Intermediate | Not Ready | ||
| 05/04/2023 | COT - LCPL - Plumbing Intermediate | Re-inspection required | 5/4/23: loose Ufer clamp connection, over-notch bearing wall studs, seal open chase in the garage, secure gas line in the laundry room. Sister a new stud to the fractured bearing wall stud in laundry, nail plate ABSA in the laundry, retype exhaust duct in laundry, over-spanned stud in non-bearing wall in laundry. INSPECTION STOPPED. MORE ITEMS MAY BE ADDED. | |
| 05/08/2023 | COT - LCPL - Plumbing Intermediate | Canceled | 5/4/23: loose Ufer clamp connection, over-notch bearing wall studs, seal open chase in the garage, secure gas line in the laundry room. Sister a new stud to the fractured bearing wall stud in laundry, nail plate ABSA in the laundry, retype exhaust duct in laundry, over-spanned stud in non-bearing wall in laundry. INSPECTION STOPPED. MORE ITEMS MAY BE ADDED. 5/8/23: inspection canceled by Chris Suda |
|
| 05/09/2023 | COT - LCPL - Plumbing Intermediate | Re-inspection required | 5/4/23: incomplete plans (missing electrical), GEC not connected to Ufer, over-notching in bearing wall studs, insulate behind the tub, nail plate romex, add smoke det outside front bedroom, over-notch non-bearing wall studs. INSPECTION STOPPED. MORE ITEMS MAY BE ADDED. 5/4/23: loose Ufer clamp connection, over-notch bearing wall studs, seal open chase in the garage, secure gas line in the laundry room. Sister a new stud to the fractured bearing wall stud in laundry, nail plate ABSA in the laundry, retype exhaust duct in laundry, over-spanned stud in non-bearing wall in laundry. INSPECTION STOPPED. MORE ITEMS MAY BE ADDED. 5/4/23: loose Ufer clamp connection, over-notch bearing wall studs, seal open chase in the garage, secure gas line in the laundry room. Sister a new stud to the fractured bearing wall stud in laundry, nail plate ABSA in the laundry, retype exhaust duct in laundry, over-spanned stud in non-bearing wall in laundry. INSPECTION STOPPED. MORE ITEMS MAY BE ADDED. 5/8/23: inspection canceled by Chris Suda 5/9/23: inspection canceled by Chris Suda |
|
| 05/12/2023 | COT - LCPL - Plumbing Intermediate | Re-inspection required | ||
| 05/17/2023 | COT - LCPL - Plumbing Intermediate | Passed |