Inspection Status: Passed
Inspection History: COT - LCBU - Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 10/06/2022 |
COT - LCBU - Framing |
SCARRAZCO |
Approved |
Entered by NGARCIA3 - Approved |
| 10/05/2022 |
COT - LCBU - Framing |
SCARRAZCO |
Not ready for Inspection |
Entered by NGARCIA3 - not ready. Stud underneath stairway need to be continuous. |
| 08/23/2022 |
COT - LCBU - Framing |
TLUNDBERG |
Partial Approval |
Entered by VVERA1 - PA |
| 08/17/2022 |
COT - LCBU - Framing |
TLUNDBERG |
Denied |
Entered by VVERA1 - DE
1. Two king studs required at each end of patio door. King studs are to be continuous from base plate to top plate.
2. Remove blocks between GLB and posting by patio door.
3. Plans require 5 2x6 at mid bearing point of 5-ply truss
4. Remove mangled strap at 3-ply truss on 2nd floor and install new |