Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T22CM03905

Parcel: 141432890

Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready
11/03/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready missing rsp clips. nail off loose strap. missing blocking at landing stair way. missing anchor bolts behind shear wall and edges of plates. nail every 16” on bottom plates second floor.
11/08/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed corrections were made