Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/31/2024 | COT - HCPL - Plumbing Progress | Partial Pass | 25´ center to first light pole west of hydrant. HCS connection. At 5´ depth to sub grade. From the curb about 16´7” at entry curb at a depth of 7´. Tie in to existing reclaimed water line. Refer to padre C5.1 1/31/2024 | |
02/14/2024 | COT - HCPL - Plumbing Progress | Partial Pass | Utility plan C5.1 underground 4” sewer point of connection to 20’ from building. Point of connection with two clean outs on test. At 36” depth top of pipe. Reclcained non potable water viewed point of connection from 6” riser to first gate valve. At 36”depth top of pipe.(L4.1) 2/14/2024 |
|
02/15/2024 | COT - HCPL - Plumbing Progress | Partial Pass | C5.1. 36” depth. 2’water line type k from meter to 60’ from building. Okay to backfill progress areas. 2/15/2024 | |
03/01/2024 | COT - HCPL - Plumbing Progress | Partial Pass | Main reclaimed water line 4” to 6” from far north side to far south side 2’ from upper side walk. Top of pipe 36”. Okay to backfill progress areas. 3/1/2024 | |
06/04/2024 | COT - HCPL - Plumbing Progress | Not Ready |