Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM03251

Parcel: 141431500

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - T22CM03251

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
08/02/2022 COT - RSBU - Exterior Clips/Sheathing  TLUNDBERG Approved Entered by NGARCIA3 - AP
07/25/2022 COT - RSBU - Exterior Clips/Sheathing  TLUNDBERG Not ready for Inspection Entered by VVERA1 - NR
07/22/2022 COT - RSBU - Exterior Clips/Sheathing  TLUNDBERG Denied Entered by VVERA1 - DE 1. Extend shear wall panels to the exterior face of wall per detail. 2. Missing double studs on first floor east wall that support girder trusses. 3. Remove all metal truss spacers that are hanging loose