Permit: T22CM03251

Parcel: 141431500

Inspection Status: Not Ready

Inspection History: COT - LCBU - Framing

Permit Number - T22CM03251

Inspection Description - COT - LCBU - Framing

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - LCBU - Framing Not Ready
07/25/2022 COT - LCBU - Framing IVR USER Cancelled Entered by IVR USER - IVRS - RI canceled
11/03/2022 COT - LCBU - Framing Not Ready replace shear wall that has been cut. double studs need to be continuous for double girders. add blocking to registers. add titan bolts center third of the bottom plates. secure bracing for trusses that have been loosened. add sister stud to the loose stud on second floor 1st bedroom.
11/07/2022 COT - LCBU - Framing Passed