Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM03223

Parcel: 12403280A


Addresses:

Unknown


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - T22CM03223

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
12/18/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 12/18/23: sheathing on west side of home not nailed per schedule, hold downs not properly fastened and not in proper location, king studs missing at openings greater than 4'.
12/26/2023 COT - RSBU - Exterior Clips/Sheathing  Passed