Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
Permit Number - T22CM03088
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | COT - RSEL - Electrical Final | Not Ready | ||
04/27/2023 | COT - RSEL - Electrical Final | Not Ready | Not ready. Laundry room need to be GFCI. Outdoor receptacles are loose need to be secured with center screw. PRV needs to be 6" above grade. Clean outs need to be cut to grade. Secondary line for condensation is dripping. Condenser lines need to be UV taped. 4/27/2023 | |
05/02/2023 | COT - RSEL - Electrical Final | Passed | Approved. Corrections were made. 5/2/2023 |