Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: RSBU - Building Final
Permit Number - T22CM03088
Inspection Description - RSBU - Building Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | RSBU - Building Final | Not Ready | ||
04/27/2023 | RSBU - Building Final | Not Ready | Not ready. Laundry room need to be GFCI. Outdoor receptacles are loose need to be secured with center screw. PRV needs to be 6" above grade. Clean outs need to be cut to grade. Secondary line for condensation is dripping. Condenser lines need to be UV taped. 4/27/2023 | |
05/02/2023 | RSBU - Building Final | Passed | Approved. Corrections were made. 5/2/2023 |