Inspection Status: Not Ready
Inspection History: COT - LCBU - Building Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - LCBU - Building Final |
|
Not Ready |
|
| 09/12/2023 |
COT - LCBU - Building Final |
|
Re-inspection required |
9/12/23: waiting on Fire Final, type panel schedule, restrooms require ADA signage on outside wall, install coat hooks at 48" max off floor, install mirrors 40" max off floor to glass, flush valve required on the door side of ADA restroom, plumb 3-compartment sink so each compartment drains independently. |
| 09/21/2023 |
COT - LCBU - Building Final |
|
Passed |
|