Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Not Ready
Inspection History: COT - LCBU - Masonry Pregrout
| Date |
Description |
Inspector |
Results |
Comments |
| 10/26/2022 |
COT - LCBU - Masonry Pregrout |
|
Not Ready |
|
| 01/04/2023 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
5th lift entry columns at front entrance |
| 01/09/2023 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
partial approval for 3rd lift for header at entry |
| 01/11/2023 |
COT - LCBU - Masonry Pregrout |
|
Passed |
|
| 11/14/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
1st lift, okay to grout progress areas |
| 11/18/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
PARTIAL 2nd lift (9’ high) all S wall, 3/4 of W and E walls |
| 11/22/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
PARTIAL 3rd lift (12’ high) all S wall, 3/4 of W and E walls, okay to grout progress areas |
| 11/28/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
PARTIAL 4th lift (16’ high) all S wall, 3/4 of W and E walls, okay to grout progress areas |
| 11/30/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
PARTIAL 5th lift (top out at 24’ high) all S wall, 3/4 of W and E walls, okay to grout progress areas |
| 12/07/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
PARTIAL 2nd lift (9’ high) all North wall, remaining NW and NE walls, okay to grout progress areas |
| 12/09/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
PARTIAL 3rd lift (12' high) all North wall, remaining NW and NE walls, okay to grout progress areas |
| 12/14/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
PARTIAL 4th lift (19' high) all N wall, remaining NW and NE walls, okay to grout progress areas |
| 12/19/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
partial approval for top out of exterior wall excluding above large entry door area, ok to grout |
| 12/27/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
partial approval for 2nd lift columns at entry, and 5th lift on parapet walls at entry |
| 12/28/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
partial approval OK for third lift on columns on either side of entry and first lift on header above entry door |
| 12/30/2022 |
COT - LCBU - Masonry Pregrout |
|
Partial Pass |
partial approval for fourth lift on columns at entry |