Date Description Inspector Results Comments
10/26/2022 COT - LCBU - Masonry Pregrout  Not Ready
01/04/2023 COT - LCBU - Masonry Pregrout  Partial Pass 5th lift entry columns at front entrance
01/09/2023 COT - LCBU - Masonry Pregrout  Partial Pass partial approval for 3rd lift for header at entry
01/11/2023 COT - LCBU - Masonry Pregrout  Passed
11/14/2022 COT - LCBU - Masonry Pregrout  Partial Pass 1st lift, okay to grout progress areas
11/18/2022 COT - LCBU - Masonry Pregrout  Partial Pass PARTIAL 2nd lift (9’ high) all S wall, 3/4 of W and E walls
11/22/2022 COT - LCBU - Masonry Pregrout  Partial Pass PARTIAL 3rd lift (12’ high) all S wall, 3/4 of W and E walls, okay to grout progress areas
11/28/2022 COT - LCBU - Masonry Pregrout  Partial Pass PARTIAL 4th lift (16’ high) all S wall, 3/4 of W and E walls, okay to grout progress areas
11/30/2022 COT - LCBU - Masonry Pregrout  Partial Pass PARTIAL 5th lift (top out at 24’ high) all S wall, 3/4 of W and E walls, okay to grout progress areas
12/07/2022 COT - LCBU - Masonry Pregrout  Partial Pass PARTIAL 2nd lift (9’ high) all North wall, remaining NW and NE walls, okay to grout progress areas
12/09/2022 COT - LCBU - Masonry Pregrout  Partial Pass PARTIAL 3rd lift (12' high) all North wall, remaining NW and NE walls, okay to grout progress areas
12/14/2022 COT - LCBU - Masonry Pregrout  Partial Pass PARTIAL 4th lift (19' high) all N wall, remaining NW and NE walls, okay to grout progress areas
12/19/2022 COT - LCBU - Masonry Pregrout  Partial Pass partial approval for top out of exterior wall excluding above large entry door area, ok to grout
12/27/2022 COT - LCBU - Masonry Pregrout  Partial Pass partial approval for 2nd lift columns at entry, and 5th lift on parapet walls at entry
12/28/2022 COT - LCBU - Masonry Pregrout  Partial Pass partial approval OK for third lift on columns on either side of entry and first lift on header above entry door
12/30/2022 COT - LCBU - Masonry Pregrout  Partial Pass partial approval for fourth lift on columns at entry