Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - T22CM02472
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | 1/14/25 fire caulking needed in penetrations to top plate, including where plumbing in run through, anchor bolts missing as well as missing the square plates as stated in the notes for the foundation plan. Gas pressure gage broken, unable to confirm pressure test. Stopped inspection. | |
| 01/29/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 1/29/25 1. Wires in bedrooms need to be 12/2 per plan 2. Need to update electrical plan to reflect multiple outlets and breakers. 3. Main panel is located in bedroom not per plan; plan shows the main panel in the exterior. 5. Weatherproof GFCIs missing on the exterior. 6. Clean out missing northeast side of house exterior. 7. Mini splits are not in yet. |
|
| 05/08/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Approved. All corrections have been made. No other items pending. 5/8/2025 | |
| 09/26/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 9-26-2024, stopped inspection after noting: missing anchor bolts on sill plate & fire caulking throughout top plates together with missing receptacles within 6 feet of an opening and gas not pressurized at time of inspection. Customer asked to reschedule when ready. |