Permit: T22CM01656

Parcel: 133425690

Inspection Status: Not Ready

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
10/27/2022 COT - RSME - Mechanical Final  Not Ready
07/25/2022 COT - RSME - Mechanical Final  DQUINN Denied Entered by VVERA1 - denied Per code, condensate drains must terminate onto an absorbent surface, as apposed to the concrete sidewalk where it presently terminates. Constant dripping will create black mold and green fungi, which will turn into a slippery surface in the walkway. The alternatives are to cut a drain through and under the sidewalk to an absorbent surface, or pipe it into the tail piece drain of a sink. These are the only 2 alternatives for this situation.
09/18/2023 COT - RSME - Mechanical Final  Not Applicable
11/29/2022 COT - RSME - Mechanical Final  Passed