Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM01013

Parcel: 124062560

Inspection Status: Partial Pass

Inspection History: COT - RSPL - Rough Soil 

Permit Number - T22CM01013

Inspection Description - COT - RSPL - Rough Soil 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
02/02/2023 COT - RSPL - Rough Soil  Partial Pass Inspection should read masonry pre-grout at first lift (0’ - 4K’). Ok to place grout in progress areas.
03/06/2023 COT - RSPL - Rough Soil  Passed
09/28/2023 COT - RSPL - Rough Soil  Passed
12/30/2022 COT - RSPL - Rough Soil  Not Ready Inspection should read excavation layout/rebar: Footings are correct; Ok to place concrete in progress areas.