Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 10/04/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
TLUNDBERG |
Approved |
Entered by NGARCIA3 - AP |
| 09/30/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
SCARRAZCO |
Not ready for Inspection |
Entered by VVERA1 - Not ready. 10’ clearance fresh air intake |
| 09/15/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
TLUNDBERG |
Denied |
Entered by NGARCIA3 - DE
1. Vents are dry
2. Fresh air intake is within 10 feet of a vent
3. Block and seal AC chase at floor and ceiling
4. Water test tubs and showers
5. Maintain min 1 inch clearance from B-vent to combustibles
6. Reinforce top plate at B-vent & block all holes |