Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM00359

Parcel: 133553310


Addresses:

250 S VOZACK LN


Inspection Status: Not Ready

Inspection History: COT - LCME - Mechanical Final 

Permit Number - T22CM00359

Inspection Description - COT - LCME - Mechanical Final 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/26/2022 COT - LCME - Mechanical Final  Not Ready
10/16/2023 COT - LCME - Mechanical Final  Re-inspection required 10/16/23: wrap exterior water lines with R-3 insulation and UV resistant tape, all exterior outlets required to be WR, remove ALL construction debris & materials from interior and exterior on site, type all panel schedules, flush floor drain at dining room, install all adjustable hand shower on a vertical bar per 608., Fire Dept and Site Engineering have not signed off. INSPECTION STOPPED. MORE ITEMS MAY BE ADDED AT NEXT INSPECTION.
10/17/2023 COT - LCME - Mechanical Final  Not Ready 10/16/23: wrap exterior water lines with R-3 insulation and UV resistant tape, all exterior outlets required to be WR, remove ALL construction debris & materials from interior and exterior on site, type all panel schedules, flush floor drain at dining room, install all adjustable hand shower on a vertical bar per 608., Fire Dept and Site Engineering have not signed off. INSPECTION STOPPED. MORE ITEMS MAY BE ADDED AT NEXT INSPECTION.
10/17/23: I called Steve Stratigouleas and he stated that Fire & Site Engineering have not inspected yet, and none of the corrections from 10/16/23 have been completed. I informed Steve to not recall for a final building inspection until the above are completed. I also informed Steve that more corrections may be added to the list, as I stopped the inspection mid-way due to excessive corrections.
12/22/2023 COT - LCME - Mechanical Final  Passed