Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - LCBU - Building Above Ceiling
Permit Number - T22CM00359
Inspection Description - COT - LCBU - Building Above Ceiling
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2022 | COT - LCBU - Building Above Ceiling | Not Ready | ||
04/18/2023 | COT - LCBU - Building Above Ceiling | Re-inspection required | 4/18/23: seal all penetrations in top plate and around OSB at top of chases,open condensate line, connect exhaust to ceiling units and seal, attic access opening is too small to remove and replace unit (IRC 1401.2), Remove all obstructions and material in the access opening, smoke det are not wired. This inspection was stopped in the 3rd room inspected. More items maybe added to the next inspection. |
|
04/24/2023 | COT - LCBU - Building Above Ceiling | Re-inspection required | 4/18/23: seal all penetrations in top plate and around OSB at top of chases,open condensate line, connect exhaust to ceiling units and seal, attic access opening is too small to remove and replace unit (IRC 1401.2), Remove all obstructions and material in the access opening, smoke det are not wired. This inspection was stopped in the 3rd room inspected. More items maybe added to the next inspection. 4/24/23: Contractor walked inspection with me and generated a list, remove 2x4 blocks in ceiling service holes, remove fire alarm wire from service holes, FIRE STOP all holes in top plate, all valves to be accessible. Domestic water lines tested and approved, gas lines tested and approved. |
|
04/26/2023 | COT - LCBU - Building Above Ceiling | Passed |