Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: RESIDENTIAL INTERMEDIATE
Permit Number - T22CM00260
Inspection Description - RESIDENTIAL INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/03/2022 | RESIDENTIAL INTERMEDIATE | Approved | Approved | |
06/02/2022 | RESIDENTIAL INTERMEDIATE | Correction Required | CO 1. Block registers 2. Install smokie in master bedroom 3. Burn in the line-set 4. Post the 3-ply girder in the garage. |
|
05/31/2022 | RESIDENTIAL INTERMEDIATE | Cancelled | CA per on site conversation. |