Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: Pool/Spa - Pre-Gunite
Permit Number - T22BU00183
Inspection Description - Pool/Spa - Pre-Gunite
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/19/2022 | Pool/Spa - Pre-Gunite | TLUNDBERG | Denied | Entered by NGARCIA3 - DE The existing retaining wall on south end of pool was omitted on site plan submitted to COT. This retaining wall is retaining 40” of earth and 68” of lateral force to the higher wall. This existing retaining wall has no footing and is stacked block without any mortar joints. The pool rebar cage is directly against the exposed base course. New engineering by the engineer of record (Alan Money) will be required to address this issue. Submit this new engineering and a revised & accurate site plan for new review. Cancel all other inspections |
10/26/2022 | Pool/Spa - Pre-Gunite | Not Ready | ||
05/10/2023 | Pool/Spa - Pre-Gunite | Passed | ||
10/28/2022 | Pool/Spa - Pre-Gunite | Re-inspection required | ||
11/01/2022 | Pool/Spa - Pre-Gunite | Re-inspection required | pool builder to RFI Engineer of Record (AMEX Engineering) about existing 40” high retaining wall adjoining the pool shell to the south end. Direction from the EofR to be on his letterhead and a copy placed on site for the city inspector at next inspection. |