Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T22BU00163

Parcel: 103200700


Addresses:

2835 W KELSO PL

Inspection Status: Partial Pass

Inspection History: COT - RSBU - Stem Wall/Retaining Wall 

Date Description Inspector Results Comments
09/16/2022 COT - RSBU - Stem Wall/Retaining Wall  TGAUSP Partial Approval Entered by NGARCIA3 - Partial for approximately 125 linear feet of site retaining walls. Poured in place stepped from 5’ to 10’, okay for concrete placement
10/26/2022 COT - RSBU - Stem Wall/Retaining Wall  Not Ready
11/29/2023 COT - RSBU - Stem Wall/Retaining Wall  Partial Pass 20’. Last of retaining wall. Rebar in footing per plan. Okay for concrete placement. 11/29/2023
12/05/2023 COT - RSBU - Stem Wall/Retaining Wall  Passed 12/5/2023 The remaining 20' of retaining wall. Verticals and horizontals per plan. Okay for concrete placement.