Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Stem Wall/Retaining Wall
| Date |
Description |
Inspector |
Results |
Comments |
| 09/16/2022 |
COT - RSBU - Stem Wall/Retaining Wall |
TGAUSP |
Partial Approval |
Entered by NGARCIA3 - Partial for approximately 125 linear feet of site retaining walls. Poured in place stepped from 5’ to 10’, okay for concrete placement
|
| 10/26/2022 |
COT - RSBU - Stem Wall/Retaining Wall |
|
Not Ready |
|
| 11/29/2023 |
COT - RSBU - Stem Wall/Retaining Wall |
|
Partial Pass |
20’. Last of retaining wall. Rebar in footing per plan. Okay for concrete placement. 11/29/2023 |
| 12/05/2023 |
COT - RSBU - Stem Wall/Retaining Wall |
|
Passed |
12/5/2023 The remaining 20' of retaining wall. Verticals and horizontals per plan. Okay for concrete placement. |