Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T21RW03832

Parcel: 113110270


Addresses:

2317 N MARTIN AV


Inspection Status: Re-inspection required

Inspection History: TRSP - ROW - Recurring

Permit Number - T21RW03832

Inspection Description - TRSP - ROW - Recurring

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
09/28/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Drillmmax finished asphalt patching. Cleaning up roadway and pushing asphalt to side for later pick up.
09/28/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Drill max arrived at 0745 notified work could t begin until 0900 per plans. Drill max placing asphalt. Tac was not used on existing asphalt or curb asphalt was placed and tac to be placed as crack seal on top. Asphlt meets specs.
09/28/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
09/24/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Bore completed. Box has been placed site being cleaned and cold patch placed. Asphalt set to be placed Monday.
09/28/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
09/24/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Drill max began trenching and bore pit and potholes at 0800. Permit states start time 0900-1530. Time change was denied by COT permitting. Notified sydnie with drill max that construction cannot begin before 0900. Boring south to pole to place hand hole. No standby available for gas trenching cannot resume today. Trenching done yesterday must be redone and compacted with visual inspection. drill max states if they have time today they will omit if not Monday compaction with visual inspection will be done again.
09/24/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
09/23/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Drill max trenching continues south to swf pole from alley way.
09/23/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
09/22/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Drill max went to get more AB and cold patch. Asked them to AB half the driveway width for homeowners if needed to enter or exit. Cold patch must be placed over night. Dan Robertson coming to check on site in a hour.
09/22/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Continued
09/22/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Drill max open trenching for fiber from alley to swf pole
09/22/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
09/21/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Drill max trenching from pole across alley to street. Going to place riser and conduit to street. Going to talk to Brian Ripley about bore tomorrow or open trench the ground is very hard and having issues getting through it
09/21/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.
11/08/2022 TRSP - ROW - Recurring Not Ready No activity
02/15/2023 TRSP - ROW - Recurring Passed Work completed area restored.