Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T21RW01667

Parcel: Unknown


Addresses:

306 E ELM ST


Inspection Status: Re-inspection required

Inspection History: TRSP - ROW - Recurring

Permit Number - T21RW01667

Inspection Description - TRSP - ROW - Recurring

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/13/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Pole placed with proper color according to plans. Asphalt patch with hot mix. Landscaping has been restored. Site appears to pass ROW Final inspection
08/13/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site.
07/27/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Tucson asphalt cutting bore locations compacting and placing hot mix asphalt.
07/28/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site.
07/21/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Landscaping is restored. Pending asphalt hot patch. Barricades need to be removed from site. Notified Ed with Enertech that plates need to be reccessed or removed and cold patched per city specs. He said they are hot patching at end of week he will not recess or cold or hot before then. Site does not pass ROW inspection
07/27/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control devices have been removed from site.
06/11/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Crew finishing boring. Trenches covered by steel plates and cold patch. Concrete and slurry set for Monday or Tuesday next week.
07/21/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control devices removed from roadway, staged for set up/pickup.
06/03/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Begin vacuum trench for pole and hand boxes. Asked home owners to
Move vehicles so debris from vacuum truck don’t get on vehicles. Trenching has begun for pole.
06/11/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control needs maintenance missing road closure with detour sign notified Jamie at trafficade one is being sent out.
05/25/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - Pre con meeting with Enertech. Remove one pole with light (wood) replace with new small cel antenna pole. Pedestal will be in alley way near pole. Shared power site. Bore will go under landscaping island in roadway. TEP will need to remove power to pole for light. Traffic control plan will need to be revised for 5th street and alley way. Waste management to be called for schedule and notification of work. Landscaping to be restored upon completion of project.
06/10/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control needs maintenance flaggers are on the way only 14’ of roadway is usable. Notified Enertech and trafficade traffic control must be set according to plan and flaggers needed for less than 20’ of usable roadway.
05/10/2021 TRSP - ROW - Recurring Re-inspection required TDOT-EXCAV GENERAL INSPECTION - No work on pole
06/03/2021 TRSP - ROW - Recurring Re-inspection required TDOT-Routine Barricade Inspect - Traffic control is set according to plan.