Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T21OT00827

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
07/27/2022 COT - ENGR - Signage Final hthrall1 Approved Entered by HTHRALL1 -
07/27/2022 COT - ENGR - Signage Final hthrall1 Continued Entered by HTHRALL1 - REVISED PLANS SUBMITTED FOR CONSTRUCTION NOTATIONS. APPROVED ON 07/27.
02/28/2022 COT - ENGR - Signage Final hthrall1 Continued Entered by HTHRALL1 - SDRC CASE MSP-22-02 APPROVED / T22SA00048 INCREASE MONUMENT SIGN AREA FROM 50 TO 60 SQFT ALLOW 1 MONUMENT ON LOCAL STREET FRONT AND RETAIN 3 ALLOWED ON KINO BETWEEN TUCSON MARKETPLACE AND SOUTH PROPERTY LINE OF SUB AREA B-111. APPEAL PERIOD ENDS 3/14/22 NEEDS CONSTRUCTION PLAN SHEET UPDATED WITH NOTES FOR PERMITTING
11/10/2021 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - RE: monument sign review For: Tucson Marketplace at the Bridges AT: 1500 E Tucson Marketplace (SE corner of MLK and Tucson Marketplace) Permit: T21OT00827 Reviewer: H. Thrall Date: 11/10/21 Codes: Unified Development Code (UDC 7A, Sign Standards), National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1) Sign area exceeds allowance for a monument sign (max of 50 sqft). In addition, the bottom text needs to be included (box it). Suggest reducing cabinet height to 8' tall to allow for change from a monument to a low-profile sign category, which allows for 60 sqft sign area. Be sure though, that 2' solid base without text is provided under the full length of this sign cabinet design. The alternative is to shorten the length of the cabinet and ensure that when the bottom letters are boxed, that they do not exceed a cumulative sign display area on the structure of 50 square feet. (The similar sign on Park was a pole sign category. This site already has that. If additional pole signs are desired, a Sign Design Review Committee process applies.) 2) Acknowledged sheet 2 has a 30' setback noted. However, this is needed on site plan sheet 3 specifically, show setback from both MLK Jr Way and Tucson Marketplace Blvd curb to closest leading edge of sign. Please note - the setback for a monument is 20', setback for a low-profile sign can be 16' from curb, providing sign is out of SVT. 3) Show SVT at corner of Tucson Marketplace and MLK Jr Way to show sign is outside of it. 4) Clarify if sign is within electric easement… relocate as needed - appears it is right on top of an electric line in the site plan sheet. 5) NEC / OLC: a) Add note to timer that shut off curfew is midnight. b) Add note that all lighting is internal (is the decorative component lit? and is bottom "the Bridges" lettering lit? just add clarifying notes as needed, please) 6) IBC: a) Is side décor framework all one piece with bottom blue component? If so, add note. If not, add bolts to sign cabinet (I see in engineering plan of top view and side view where this decorative piece bolts to base, thank you.) b) Just add note clarifying all welds are shop welds. (Understood in engineering that bolting used for attachment mounts) Please revise and resubmit by email to to Heather.Thrall@tucsonaz.gov