Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Not Ready
Inspection History: COT - ENGR - Signage Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
COT - ENGR - Signage Final |
|
Not Ready |
|
| 11/19/2021 |
COT - ENGR - Signage Final |
HThrall |
Approved |
Entered by HTHRALL1 - Revised plans subitted and approved |
| 11/10/2021 |
COT - ENGR - Signage Final |
Hthrall |
Partial Approval |
Entered by HTHRALL1 - RE: sign permit review
Permit: T21OT00748
Site: 8225 E Speedway Blvd (apartments)
For: replacement monument sign (TRE 1996-042B)
Reviewer: H. Thrall
Date: 11/09/21
Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018.
1) Acknowledged existing sign Temporary Revocable Easement (TRE) 1996-042B to be used again for sign replacement, signed copy received, location ok and matches TRE and code minimum setback of 20' from street curb.
2) NEC / OLC - add note 'existing power to be utilized'
3) Construction -
a) Provide notations how cabinet mounted to support pole (i.e. bolted saddle plates?)
b) Provide clarification if any field welds will be done on the top plate - note that special inspection is required for that and a form is required to be filled out by an engineer ahead of time if that circumstance applies.
Send revision to Heather.Thrall@tucsonaz.gov
|