Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T21OT00581

Parcel: 12212010B


Addresses:

4645 E SPEEDWAY BL


Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T21OT00581

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
03/04/2022 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Revision received to issued permit and SDRC case. Review is as follows now for a pole sign instead of a monument sign RE: review of revision For: change from monument to pole sign category Site: 4645 E Speedway Bl / Mission Plaza Reviewer: H. Thrall Date: 2/28/22 Permit: T21OT00581 (revision) Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1) UDC 7A Sign Standards: a) Provide permit application b) Sign area requires revision - include the area on the "topper" that reads "Mission Plaza" and fully dimension. (**SDRC case required for exceeding 72 sqft sign area of pole sign **) c) Call out the topper as a site identifier for clarification that this is an area in addition to the maximum of 8 tenant panels below the topper element d) Height of the sign is to be taken from top of street curb to top of the sign topper, as the name of the plaza is on this sign element. e) Side view of the sign does not match the base, update to show rock f) Prior SDRC case was for a monument sign reduced setback. ***This revision from a monument to a pole sign category requires this case to change to a reduction for a setback for a pole sign to be reduced from 30' to 12' from curb.*** g) Revise Speedway sign setback diagram to indicate pole sign, not a monument sign. h) Did the SWAN monument get installed under permit T21OT00581 from the original SDRC case? If so, show the picture of that sign installation on the diagram for the revised SDRC case. If not, and if it will not be installed, specify by sending letter to staff on your company letterhead or email indicating the sign will not be installed and it will be added to the permit file. 2) NEC: No comments 3) OLC: a) Note that the shut off for the timer is a curfew of midnight 4) IBC: a) this is an old, existing sign base, footer unknown at this time. Verify footer size and integrity to support larger cabinet (i.e. with an underground probe inspection? Engineer can do) b) sign support pole - has this been verified for the size ? Send revisions to Heather.Thrall@tucsonaz.gov with updated SDRC applications
10/21/2021 COT - ENGR - Signage Final Hthrall Approved Entered by HTHRALL1 - Revised plan received 10/18/21 was approved 10/21/21.
10/14/2021 COT - ENGR - Signage Final Hthrall1 Partial Approval Entered by HTHRALL1 - RE: 3rd sign review For: monument AT: 4645 E Speedway Bl Permit: T21OT00581 Reviewer: H. Thrall Date: 10/14/21 1) Acknowledged proposal approved for reduced setback for sign to 12' from Speedway face of curb under SDRC case MSP-21-10 / T21SA00322. The following review applies to construction aspects for the permit record. 2. Resubmittal has a 2nd sign - a replacement sign, for Swan side. 3) Structural: B) indicate how cabinet mounted to pipe (i.e. bolted saddle at top, etc.) size and number of bolts? 4) Site plan: A) provide enlarged site plan that shows property line and sight visibility triangle off Swan B) provide 2' setback from the parking area access lane to the western leading edge of the sign C) dimension the island and indicate 18 inches provided adjacent to parking space D) dimension that the sign is 2' away from driveway curb edging to the south E) indicate if the landscaping will be removed F) take the sign setback from the flat face of Swan street curb to the eastern leading edge of the sign (provide 20' minimum) and ensure sign on private property (mark lot line / show lot line on plan). G) If you need information related to site plan criteria, reach out to reviewer. Return revised plan set to Heather.Thrall@tucsonaz.gov
10/14/2021 COT - ENGR - Signage Final Hthrall1 Continued Entered by HTHRALL1 - resubmittal received on 10/14/21 - includes a sign on Swan (replaces existing / matches design of the sign just approved from the SDRC for the reduced setback off Speedway)
10/11/2021 COT - ENGR - Signage Final Hthrall Partial Approval Entered by HTHRALL1 - RE: 2nd sign review For: monument AT: 4645 E Speedway Bl Permit: T21OT00581 Reviewer: H. Thrall Date: 10/11/21 1) Acknowledged proposal approved for reduced setback for sign to 12' from Speedway face of curb under SDRC case MSP-21-10 / T21SA00322. The following review applies to construction aspects for the permit record. 2) Electrical / Outdoor Lighting Code: A) note sign will use existing power (replacement sign) B) list volts / amps / circuits C) indicate where shut of switch is located D) indicate where dedicated circuit is located E) indcate sign lighting type (i.e. LED) F) add note sign lighting shall not exceed 4400k temperature G) add note timer shall be provided / curfew of midnight for shut off H) add note for timer location 3) Structural: A) provide footer size & pipe size B) indicate how cabinet mounted to pipe (i.e. bolted saddle at top, etc.) C) indicate how topper and base design are installed D) note whether field welds applicable. If so, special inspection required Return revised plan set to Heather.Thrall@tucsonaz.gov
10/11/2021 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - T21SA00322 / MSP-21-10 - approved reduced setback via Director's Notice of Decision (SDRC reviewed via design professional in lieu of quorum). Appeal ends 10/08/21
08/23/2011 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Referred on 08/23/2021 to SDRC review process for reduced sign setback (from 20' to 12').