10/27/2022 | COT - ENGR - Signage Final | Not Ready | ||
08/23/2022 | COT - ENGR - Signage Final | hthrall1 | Approved | Entered by HTHRALL1 - TRE 2021-143 was released on 8/22/22 to allow the monument sign in the right of way. |
05/07/2021 | COT - ENGR - Signage Final | Hthrall | Partial Approval | Entered by HTHRALL1 - RE: digital monument sign in right of way AT: 8325 E Golf Links Road (A-family Storage) Sign permit: T21OT00285 Reviewer: H.Thrall Date: 05/07/2021 (2nd review) Permit status: partial approval just for monument sign- awaiting TRE review process Codes: Unified Development Code (UDC) Sign Standards 7A, National Electrical Code (NEC), Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1) Temporary revocable easement required to place sign in the right of way. This review serves as referral for that process through the Dept of Transportation & Mobility (DTM) Real Estate Division. Contact is Michael.Hollar@tucsonaz.gov Understood sign setback is 20' from curb, ok to proceed. 2) Revise app to provide all details for the monument sign (it's blank application) 3) revise plan set to remove all mention of wall sign, as it has been submitted separately under T21OT00363. 4) National Electrical Code / Outdoor Lighting Code: A) Note location of timer for inspections (i.e. in office next to breaker panel…?) 5) IBC 2018: A) Engineering and attachments for monument approved, thank you. Send revisions to Heather.Thrall@tucsonaz.gov |
04/13/2021 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - RE: digital monument sign in right of way AT: 8495 / 8325 E Golf Links Road (A-family Storage) Sign permit: T21OT00285 Reviewer: H.Thrall Date: 4/12/21 Codes: Unified Development Code (UDC) Sign Standards 7A, National Electrical Code (NEC), Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1) Temporary revocable easement required to place the sign in the right of way. This review may serve as the referral for that process through the Dept of Transportation & Mobility (DTM) Real Estate Division. Contact is Michael.Hollar@tucsonaz.gov final location for the sign should be shown on the site plan - verify setback. 2) Sign elevation diagram shows 30' setback from leading edge of sign to face of street curb. However, site plan shows only a 20' setback from face of curb to leading edge of sign. Clarify for both the sign permit process and the TRE. (The minimum setback for a monument sign is 20' from f.o.curb.) 3. On sign area - elevation view sheet, just provide note that "address and address bar excluded from sign area". National Electrical Code / Outdoor Lighting Code: 4) A) Provide notation that: digital sign shall be FCC compliant. B) Provide notation that sign is to be controlled by a timer C) Note location of timer D) Provide notation that static sign maximum color temperature is 4400k E) Provide notation that digital sign component shall dim to 200 Nits from sunset to close of business or midnight curfew, and then shut off via timer. F) call out the method of dimming for the digital sign component (i.e. photocell ,etc. and location on the sign) G) add note "for digital sign - maximum rate of change is 1 x per minute - and without animation of any means" H) call out "separate electrical permit required for power to sign" I) list the volts, amps, circuits J) add note where dedicated sign circuit to be located 5) IBC 2018: A) Engineering approved, thank you. B) provide notation how cabinet is mounted to pole (il.e. saddle / bolt system - and at what points on sign support pole) C) provide notation how digital signs mounted to sign frame D) provide notation how metal skirting is mounted to sign frame E) provide notation "no field welds" to be used Send revisions to Heather.Thrall@tucsonaz.gov |