Permit: T21OT00175

Parcel: 136261290

Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T21OT00175

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
03/22/2022 COT - ENGR - Signage Final DROBERTS Partial Approval Entered by VVERA1 - IS PARTIAL AT THIS TIME, THE FOLLOWING ITEMS WILL NEED TO BE COMPLETED PRIOR TO SCHEDULING THE FINAL INSPECTION. PROVIDE PHOTOS OF THE FOLLOWING: 1) A TIMER THAT SHOULD BE LOCATED NEAR THE ELECTRICAL SOURCE. 2) LOCK OUT OR DISCONNECT SWITCH ON OR WITHIN THE SIGN CABINET. 3) COMPANY STAMP ALONG WITH UL STICKER ATTACHED THE THE SIGN STRUCTURE. 4) A MARKED 20 AMP CIRCUIT ON THE ELECTRICAL FOR THIS SIGN. 5) SHOW ME A CLEAN PANEL WITH THE PROPER GROUND WIRE AND PROTECTIVE WIRE NUTS IN PLACE.
02/08/2022 COT - ENGR - Signage Final MHERNANDEZ Cancelled Entered by NGARCIA3 - RESCHEDULE FOR ANOTHER DAY.
11/02/2021 COT - ENGR - Signage Final DROBERTS Not ready for Inspection Entered by NGARCIA3 - SING INSPECTION IS NOT READY AT THIS TIME, PROVIDE A COMPANY PLATE ON THE EXTERIOR OF THE SIGN, AN ALL ITEMS NOTED IN THE ELECTRICAL INSPECTION COMMENTS ABOVE FOR THIS DATE. RESCHEDULE THESE INSPECTIONS ONCE THIS WORK HAS BEEN COMPLETED.
10/25/2021 COT - ENGR - Signage Final DROBERTS Continued Entered by NGARCIA3 - CONTINUED SEE ABOVE NOTES.
06/21/2021 COT - ENGR - Signage Final hTHRALL Approved Entered by HTHRALL1 - SDRC per design professional, approval recommendation to Director with Director's Notice of Decision issued 06/04/21 with appeal date ending 06/18/21 (MSP-21-05 / T21SA00165)
04/19/2021 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Plans received for resbumittal for SDRC eval on 4/19/21.
03/26/2021 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - RE: pole sign review For: Safeway Plaza / 6320 E Golf Links Road Sign permit: T21OT00175 Reviewer: H. Thrall Date: 3/26/21 Codes: Unified Development Code (UDC) Sign Standards 7A, National Electrical Code (NEC), Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC 2018) **Understood the request is a Singular Sign Design Option (SSDO)** and comments with asterisks are to refer the project forward for the proper forms to be filled out and applications filed with staff for Sign Design Committee Review (SDRC). Please double check that the application meets 7A.7.1. E design criteria and 7A.7.1.G findings. (see note 2 below). Note that the sign is in a parking lot landscape island. 1) **UDC.7A.10.2.C.2.a.1. - pole signs require minimum 30' setback from street curb to leading edge of sign. Application is providing 20' setback. SDRC required.** 2) **UDC 7A.7.1. findings require that only 8 items of information - which equivalates to 8 panels - are on a sign undergoing this process for an SSDO. Please request in the application that the sign also be allowed the additional 9th item of information to identify the site (Safeway Plaza / logo).** 3) UDC 7A.10.2.C.2.a.1 - pole sign maximum sign area is 72 square feet. The sign area provided on the application exceeds that, but is not measured on the diagrams as the sum of each raised panel and then boxed site identifier / logo. Please check / revise / update, or SDRC is required to exceed 72 sqft. Total sign area on the sign. (Addresses do not count toward sign area.) 4) Acknowledged the sign will be less than 12' tall to top of letters, however, no dimension is provided from top of street curb to the top of the raised lettering of the site identifier on the structure. 5) On overview map on sheet 3, point out existing center sign on Golf Links, and the existing Jack in the box sign and the existing panda express sign. (the convenience store lot is not part of this premise) point out the existing sign that is being removed from the Wilmot side. 6) On the overview map on sheet 3, call out the entire premise lot line frontage (linear feet) on Golf Links and on Wilmot (all parcels but the convenience store parcel). 7) National Electrical Code/ Outdoor Lighting Code: a) Provide notation that maximum color temperature of the lighting will not exceed 4400k b) Provide notation that a timer will be provided to ensure curfew of midnight is achieved, and list timer location. c) Increase font to 12 point in the LED diagram… can't read it… 8) Provide basic construction information: a) Ensure the surface color and embellishments are labeled with material type to match the existing sign on Golf Links (as part of the SDRC process) b) Provide notation that "engineered plans and calculations to be provided for footer and pipe support, at Risk Category II" Please send revised plans to Heather.Thrall@tucsonaz.gov with the SDRC applications for items 1 & 2.
03/18/2021 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Resubmittal received. Emailed contractor 3/18 asking to provide 18" clear either side of sign to parking space and 2' clear behind sign to the driveway.
03/09/2021 COT - ENGR - Signage Final Hthrall Continued Entered by HTHRALL1 - Emailed applicant and contractor on March 9th to provide volts/amps/circuits/shut off switch/4400k maximum internal color temp noted, basic construction detail (engineering can be later), connection details to pole, photos of existing signs and will require all dimensions in decimal feet rather than inches. Will require SDRC review for reduced setback of 20' for a pole sign, rather than 30' setback from street curb.