Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T21OT00175

Parcel: 136261290

Inspection Status: Passed

Inspection History: SPECIAL INSPECTION - Sign Footing (Third Party)

Permit Number - T21OT00175

Inspection Description - SPECIAL INSPECTION - Sign Footing (Third Party)

Inspection Status - Passed

Date Description Inspector Results Comments
07/30/2021 SPECIAL INSPECTION - Sign Footing (Third Party) DROBERTS Approved Entered by VLEON1 -
06/23/2021 SPECIAL INSPECTION - Sign Footing (Third Party) Hthrall Continued Entered by HTHRALL1 - 3 SETS OF INSPECTIONS HAPPEN UNDER EXCAVATION: 1 - SETBACK FROM WILMOT STREET CURB 20' TO LEADING EDGE OF SIGN, EITHER MARK CENTER OF HOLE OR PROVIDE HOLE 2 - GRADE DIFFERENTIAL - HEIGHT CHECK FOR DIFFERENCE FROM TOP OF STREET CURB TO GRADE AT PROPOSED SIGN BASE IS CHECKED TO MAKE SURE SIGN WILL NOT EXCEED 12' TOP OF CURB TO TOP OF RAISED SIGN LETTERING ON STRUCTURE. 3 - THIS IS AN ENGINEERED SIGN, SO THE FOOTER SIZE - DEPTH AND DIAMETER WILL BE CHECKED BEFORE CONCRETE POUR