Permit: T21OT00089

Parcel: 10409001C


Addresses:

4365 N ORACLE RD


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T21OT00089

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
03/17/2021 SIGN SITE REVIEW Approved
03/09/2021 SIGN SITE REVIEW Continued Resubmitted plans and application for review on 3/9/21.
02/05/2021 SIGN SITE REVIEW Continued RE: sign review
For: wall / monument sign repair
AT: 4365 N Oracle / CVS
Sign permit: T21OT00089
Reviewer: H. Thrall
Date: 2/5/21

Codes: Unified Development Code (UDC) Sign Standards 7A, National Electrical Code (NEC), Tucson Pima County Outdoor Lighting Code (OLC), and International Building Code (IBC) 2018.

Enlarge font throughout the plan set to a minimum of 12 point.
1. UDC / Sign Standards:
A: Provide overview plan of sign locations on an aerial photo with both dimensioned property lines and building footprints for evaluation of sign area. Sign area is based on street development frontage, including for calculating freestanding sign allowances / size.

B: Break down sign area of channel lettering and logos as follows:
For stacked signs, separate into separately dimensioned lines
Dimension all logos separate
Once logos are boxed, if more negative space is utilized within the box, count only the positive space toward sign area
Dimension the body of the wording on the raised channel letters, descenders / ascenders do not need to be included per Sign Code Admin policy circa 2013, as they are not capitalized nor exaggerated (i.e. no elongated "p, h, or letter y" in pharmacy)
Then adjust plans and application into actual utilized sign area, per above aspects.

C. Provide a total sign area used for each building elevation. Note, the south elevation sign area will be derived off Oracle Road Frontage, as will the east elevation. The north and west elevation signage will be derived off the Wetmore Road frontage. (Use property line.)
(Not to cover more than 30% of any building elevation.)

D. Any window sign or signs under 12 sqft in area are interior site signs and do not need to be included on the application unless they need to be evaluated for illumination.

E: Freestanding sign: dimension the cabinetry (not to exceed 50 sqft)

2. NEC / OLC:
A) Provide note next to each illuminated sign: maximum interior illumination color temperature 4400K (OLC)
B) Provide note next to each illuminated sign: timer provided set to curfew of midnight or when the business closes, the later hour applies.
C) List volts, amps, circuits for each sign
D) List location of timer / circuit (i.e. in riser room in building ,etc.)
E) New cabinetry calls for details on the freestanding sign for illumination factors (volts, amps, circuits, timer, shut off, 4400k color temp, etc.)

3. IBC: provide attachment details for the cabinetry within the freestanding sign structure. This is a repair and change of copy, and a different mechanism of sign illumination from a digital message center to a static message, and hence, will be different cabinets.

Further review comments may be forthcoming, depending upon responses provided.

Please feel free to connect with the reviewer with any questions. Revised plans may be sent to Heather.Thrall@tucsonaz.gov