Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - ENGR - Signage Final
Permit Number - T21OT00086
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | COT - ENGR - Signage Final | Not Ready | ||
05/23/2022 | COT - ENGR - Signage Final | Hthrall | Approved | Entered by HTHRALL1 - Plans resubmitted 5/23/22 were reviewed / approved |
05/18/2022 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - RE: monument sign review For: 8600 E Speedway / A-family storage Sign Permit: T21OT00086 Date: 2/19/21 (2nd review 5/18/22) Reviewer: H.Thrall Codes: National Electrical Code (NEC), Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018, Unified Development Code (UDC) Sign Standards 7A 1) National Electrical Code B) call out shut off switch location - and specify if separate shut off switches for the LED message center and for LED static panel C) provide statement LED message board is FCC certified to not interfere with telecommunications (Note, several units have been found to cause disturbance, check with manufacturer) D) List manufacturer and make/model of the LED message center E) call out location for designated circuit F) provide notation that power to be provided by separate electrical permit to sign, by licensed electrician 2. Outdoor Lighting Code: A) (clarify comment - "automatically dims" - HOW?) Provide notation that LED message center dims to 200 NITS light brightness via controller from sunset to midnight curfew B) (same as above) Identify method of dimming (i.e. photocell? laser sensor?) and point out the location on the sign where this is for inspection 3. IBC A. adjust sheet 2 footer diagram to match footer dimensions of engineering (not addressed) B. clarify if using 8 inch pipe per sheet 1 or 5 inch per engineering 4. UDC 7A Sign Standards: C. provide note "sign is in city right of way, proposed per Temporary Revocable Easement" and "sign shall be removed at no expense to the city at future road widening. D. provide sight visibility triangle on the plan, taken from the driveway edge, 20' stem depth, at 345' long (sign would be out of SVT if at 20' setback) Temporary Revocable Easement has been issued TRE202-114. As soon as all comments addressed, permit can be issued. Please return plan corrections to Heather.Thrall@tucsonaz.gov |
05/03/2022 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - RE: Needs electrical / mounting clarifications addressed. TRE was just released, 2021-114. Emailed contractor. |
02/19/2021 | COT - ENGR - Signage Final | HTHRALL | Continued | Entered by HTHRALL1 - RE: monument sign review For: 8600 E Speedway / A-family storage Sign Permit: T21OT00086 Date: 2/19/21 Reviewer: H.Thrall Codes: National Electrical Code (NEC), Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018, Unified Development Code (UDC) Sign Standards 7A 1) National Electrical Code A) call out volts, amps, circuits for sign - specify if LED message center and static cabinet have separate circuits B) call out shut off switch location - and specify if separate shut off switches for the LED message center and for LED static panel C) specify if LED message center is a master/mirror unit or two master units (i.e. both have to display same message on each side, so does one unit control both sides or does each have separate controller?) C) provide statement LED message board is FCC certified to not interfere with telecommunications (Note, several units have been found to cause disturbance, check with manufacturer) D) List manufacturer and make/model of the LED message center E) call out location for designated circuit F) provide notation that power to be provided by separate electrical permit to sign, by licensed electrician 2. Outdoor Lighting Code: A) Provide notation that LED message center dims to 200 NITS light brightness via controller from sunset to midnight curfew B) Identify method of dimming (i.e. photocell? laser sensor?) and point out the location on the sign where this is for inspection C) Call out the maximum light brightness for the top cabinet and address bar are 4400K color temperature 3. IBC A. adjust sheet 2 footer diagram to match footer dimensions of engineering B. provide notation how cabinet is mounte to pole (i.e. bolt / saddle, size of bolts and number) C. provide note "no on site welding" D. Engineering approved, thank you 4. UDC 7A Sign Standards: A. provide note on sheet 4 that points out current monument sign, and that it is to be removed B. provide notation on sheet 4 that the "minimum 20' setback is taken from leading edge of sign cabinet to face of street curb" C. provide note "sign is in city right of way, proposed per Temporary Revocable Easement" and "sign shall be removed at no expense to the city at future road widening. D. provide sight visibility triangle on the plan, taken from the driveway edge, 20' stem depth, at 345' long (sign would be out of SVT if at 20' setback) These comments may be addressed while the applicant pursues a TRE with the Real Estate Division of the Department of Transportation & Mobility. Please contact Michael.Hollar@tucsonaz.gov Please return plan corrections to Heather.Thrall@tucsonaz.gov |
01/04/2023 | COT - ENGR - Signage Final | Passed | Approved | |
01/06/2023 | COT - ENGR - Signage Final | Passed |