Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
Permit Number - T21OT00071
Inspection Description - SIGN SITE REVIEW
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/16/2021 | SIGN SITE REVIEW | Approved | ||
04/14/2021 | SIGN SITE REVIEW | Continued | Special inspection certificate received 4/14 | |
04/12/2021 | SIGN SITE REVIEW | Continued | resubmittal received 4/8/21 | |
03/24/2021 | SIGN SITE REVIEW | Partial Approval | Structural review has approved the engineering for the pipe / footer. No setback is listed on the plan. To be on site, the sign has to be 42.5' from face of curb to leading edge of the structure. Emailed the contractor at Fastsigns LJL Visual Solutions / Phx with advisement to put the sign on the development plan sheet with notation at setback to proceed. |
|
03/11/2021 | SIGN SITE REVIEW | Continued | Revision received 3/11/21 for pole sign, includes engineering diagrrams and calcs - indicates field welds. Needs special inspection form filled out. Plan set under review. | |
02/04/2021 | SIGN SITE REVIEW | Continued | Resubmittal received 2/4/21 for Carondelet wall signs. | |
01/28/2021 | SIGN SITE REVIEW | Continued | RE: sign review For: detached signs AT: 7475 S Wilmot Permit number: T21OT00071 Zone: PAD-7 Date: 1/28/2021 Reviewer: H. Thrall Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), International Building Code (IBC) 2018, and Tucson- Pima County Outdoor Lighting Code (OLC). 1. Property address has changed from 7401 S Wilmot to 7475 S Wilmot - please update plans and permit application. 2. Property within PAD-7 zoning A. UDC 7A.10.2.B. - 3 to 1 ratio of sign area allowed for signs withing this site / acknowledged sign area proposed is within allowance of Wilmot street front property line of 309 x 3 B. Wall sign permit reviewed separately for all wall signs - T21OT0070 - see those review comments. 3. Please revise plans to call out signs A, B, C, D - etc - to match the permit application, and revise the location map as well to call out signs. 4. Provide arrows from plan notes to the item referred to on the diagram. Acknowledged information is there, but the plans are hard to read / refer to without this method of information referral for quick check. 5. Enlarge all notes note to a minimum of 12 point - hard to read - and for record. 6. National Electrical Code: All notes provided, thank you. 7. Outdoor Lighting Code: All notes provided, thank you. 8. International Building Code: A. Provide mounting details for principal pole sign cabinets to pole (i.e. size and number of bolts to saddle) B. Provide engineered plans for principal pole sign - both for site welding and for wind load / pipe size and footer size sufficient for structure - as surface area exceeds 80 sq.ft. C. Dimension side view at all different width points. 9. On site map: A. Call out street front property line frontage in enlarged lettering B. Call out setback on the plan as measured from leading edge of street curb to leading edge of sign cabinet (not the rock, but the cabinet closest to the road) - appears to be approx. 42.5' from curb. (Has to be on site, and mark property line, and has to be minimum of 30' from curb to sign to meet pole sign criteria, but the right of way is larger than that 30' distance here.) C. Please use the development plan sheet sent by staff to add the sign location data - as it shows sight visibility triangle locations, and would further show the sign is outside the SVT and outside all site easements. No comments on directional signs, 4' height at 12 sqft max area allowed for this size of property. Revisions may be sent to Heather.Thrall@tucsonaz.gov |