Case: T21DV06699

Parcel: 120062260


Addresses:

232 E PALMDALE ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
09/22/2021 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY SWG: THERE WAS A SMALL FIRE TO THE GAS WATER HEATER ENCLOSURE, TFD DID RESPOND ON SEPT 11, 2021 AND THE GAS WAS SHUT OFF. CODE ENFORCEMENT WAS NOT CALL OUT TO THE INCIDENT.


ELECTRICAL: 9-22-2021 THERE IS A FRAYED EXTENSION CORD POWERING THE GAS RANGE FROM AN OUTLET ABOVE THE RANGE AREA, THE EXTENSION CORD WAS COILED UP AT THE REAR OF THE RANGE, THE BARE CONDUCTOR ENERGIZED THE GAS LINE. THE TENANT DID COMPLAIN ABOUT BEING STOCKED WHEN COOKING. TEP DISCONNECT POWER. THE GAS LINE IS NOT BONDED.


PLUMBING: SWG WAS CALLED OUT TODAY TO TURN ON THE GAS. AFTER THERE INSPECTION THEY FOUND VOLTAGE IN THE GAS PIPING AND CALLED TEP TO DISCONNECT POWER. SWG DID PIN METER OFF


MECHANICAL: N/A

REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY.