Case: T21DV06566

Parcel: 134171420


Addresses:

609 S LA VISTA PL

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
09/19/2021 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY TFD: THERE IS SEVERE FIRE DAMAGE TO A DETACHED WOOD FRAMED SHED LOCATED IN THE BACK YARD, THE SHED IS ESTIMATED AT 20 X 24 WITH DEEP CRACKS AND THE EXTERIOR HAS CHARRING ON THE ROOF DECKING AND STUDS THROUGH OUT THE ENTIRE SHED. THE SHED WAS IN CLOSE PROXIMITY TO THE REAR WOOD FRAMED ADDITION, THE WESTSIDE OF THE ADDITION HAS DISCOLORING IN 8 FOOT SECTION OF THE EAVE AREA AND THE SIDING, THE SOUTH END OF THE ADDITION HAS DEEP CRACK IN 3 FEET OF THE FASCIA THERE IS DISCOLORING TO ONE 4 X 8 SHEET OF SIDING AND THE 4 RAFTER TAILS.

THE INTERIOR OF THE ROOM IS UNFINISHED WITH 4 X 4 AREA ROOF DECKING DISCOLORED. FIRE DID NOT PENETRATE THE ROOM. THERE ARE INSPECTION 2 X 2 HOLES IN THE CEILING SHEETROCK IN THE ABUTTING ADDITION AND HALLWAY.

ELECTRICAL: THE SHED HAS BURNT AND BARE WIRING IN THE INTERIOR. THERE IS A CONDUCT RUN FROM THE SHED WHICH ENTERS THE ADDITION TO UNKNOWN LOCATION. POWER WAS ORDER OFF. TEP DID DISCONNECT POWER.


PLUMBING: N/A


MECHANICAL: N/A

REMARKS: PERMIT REQUIRED FOR ELECTRICAL REPAIRS WHICH WOULD BE TO DISCONNECT POWER TO THE SHED AND RE ENERGIZE THE HOME. A ORDER TO DEMOLISH THE SHED WILL BE FOLLOWED UP BY CODE ENFORCEMENT., THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY. OWNER TO SECURE THE DWELLING.