Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2021 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE, TFD FIREFIGHTERS HAD EXITED THE SCENE BEFORE MY ARRIVAL MET WITH OCCUPANT AND TFD INVESTIGATOR. TFD WENT OVER BURN MARKS ON THE WALL AT BOTH THE N/W AND S/W CORNERS OF THE REAR PATIO. IT DID APPEAR THAT FIRE COULD HAVE STARTED AT EITHER INTERIOR OUTLET AS WIRING WAS FIRE DAMAGED AND BEADING AT BOTH OUTLETS, AND OUTLETS WERE ON THE SAME CIRCUIT. IT WAS CLEAR THAT FIRE STARTED AT THE REAR PATIO AREA, MOVED INTO THE DININGROOM RIGHT OFF THE PATIO, AND ALSO MOVED INTO THE LIVINGROOM FROM THE FIREPLACE AREA WHICH WAS JUST OFF THE NORTH WALL OF THE PATIO. FIRE PLACE CHASE WAS FIRE DAMAGED, WALLS BURNED. THE BEDROOM ON THE 2ND FLOOR ABOVE THE PATIO HAD FIRE DAMAGED FLOOR JOISTS THAT ALSO ACTED AS RAFTERS FOR THE PATIO AND FLOOR SHEATHING ALSO RECEIVED FIRE DAMAGE. NEIGHBORING PATIO TO THE SOUTH RECEIVED MINOR FIRE DAMAGE. THERE WAS HEAVY SMOKE DAMAGE IN THE DININGROOM AND KITCHEN AND MINOR SMOKE DAMAGE THRU OUT THE HOUSE. WIRING, OUTLETS, SWITCHES AN FIXTURES RECEIVED FIRE DAMAGE IN THE DINING AREA, LIVING ROOM, FIREPLACE AREA AND UPSTAIRS BEDROOM. THE ELECTRICAL SERVICE PANEL WAS SHUT OFF AND METER BOOTED BY TEP, THERE WAS NO GAS TO THE UNIT. THE WEST AND NORTH PATIO WALL AND 2ND FLOOR BEDROOM WINDOW WAS SECURED BY ARCADIAN. A NOTICE FOR A EMERGENCY ABATEMENT AND ORDER TO VACATE WAS ISSUED TO THE OWNER AND SIGNED FOR BY THE OCCUPANT. OWNER ARRIVED AS I WAS LEAVING, I ANSWERED HER QUESTIONS BEFORE LEAVING AND SHE RECEIVED A COPY OF THE NOTICE. ISSUES WERE COVERED. COMPLIANCE/ CLOSE CASE. |