Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T21DV04602

Parcel: 130102910


Addresses:

3109 E 30TH ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/06/2021 INSP - INITIAL CODE ENFORCMENT Approved ON SITE AT PROPERTY WITH INSPECTOR VALDEZ. FOUND UNPERMITED WORK THAT WAS DONE. INSPECTOR VALDEZ SPOKE WITH COMPANY WHO DID THE WORK. STOP WORK ORDER POSTED. PERMITS REQUIRED. WILL CONTINUE TO FOLLOW UP.
08/06/2021 INSP - INITIAL CODE ENFORCMENT Approved THE COMPANY ROOTER RANGER LLC, RE-PIPED WHICH MEANS REMOVED THE HOMES EXISTING SEWER, DRAIN WASTE SYSTEM TO INCLUDE THE WATER SUPPLY LINE SYSTEM. THE COMPANY REPLACED THE EXISTING SYSTEM WITH A NEW COPPER / PEX WATER SUPPLY SYSTEM AND A NEW ABS SEWER, DRAIN WASTE SYSTEM. DURING THIS TYPE OF WORK WHICH CONSISTS OF THE HOME INTERIOR WALLS BEING OPENED AND EXPOSED. THE CONCRETE FLOORS IN THE KITCHEN AND BATHROOM WERE JACK HAMMERED OPENED. THE KITCHENS MASONRY LOAD BEARING WALL WAS NOTCHED IN 7 INCHES DEEP BY 5 INCHES IN HEIGHT WHICH SPANS 4 FEET. THE STRUCTURE INTEGRITY HAS BEEN COMPROMISED. ALL THIS WORK WAS DONE WITHOUT THE PROPER PERMITS IN ISSUED STATUS. A STOP WORK ORDER WAS POSTED ON 8/06/2021.