Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | ONSITE: LAUNDRY ROOM CEILING SHEETROCK DEFECTIVE ADVISED OWNER TO HIRE A LICENSED CONTRACTOR, SEWER WAS CAPPED , YARD IS CLEANED. ADVISED OWNER TO CALL INSPECTOR VIDAL FOR FOLLOW UP INSPECTION. CAS WILL BE CLOSED PER SUPERVIOR, THE CASE WILL BE REFERRED TO T20DV07286 | |
| 06/22/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | Came to the site per the supervisor Martin Romero to check the house and the rear sliding glass door was opened. No one found in the house and the people have just left the site. Called Arcaiden Industries to the site to have the rear sliding glass door secured. The posting of Do Not Enter is still in place in the rear of the house. RV. | |
| 06/03/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | ONSITE: REPAIRS ARE NOT COMPLETED. THE 2 INCH SEWER PIPE WAS CUT BUT BUT PROPERLY REPAIRED. THE LAUNDRY ROOM DRYWALL LID IS DILAPIDATED. THERE IS REFUSE ON THE PROPERTY. THE INTERIOR FLOORS ARE NOT CLEANED. ADVISED OWNER TO USE THE WEEKEND TO COMPLETE THE REQUIREMENTS AND CALL ON MONDAY SO AN INSPECTION CAN BE SCHEDULED. | |
| 06/02/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | ONSITE INSPECTION: THE OWNER DID REMOVE THE INTERIOR PARTITIONED WALL AND DOOR BETWEEN THE KITCHEN AND LIVING ROOM. THE ENCLOSED PATIO HAS RETURN BACK ITS APPROVED USE, THE BUILT UP BLOCK WALL, WOOD STUDS AND SIDING HAVE BEEN REMOVED. THE UNPERMITTED PEX LINES HAVE BEEN REMOVED. THE JMV WAS REMOVED, HE STATED HE WILL HAVE THE REST COMPLETED BY TOMORROW. A FOLLOW UP INSPECTION HAS BEEN SCHEDULED FOR TOMORROW AT 2:00 P.M. THE FOLLOWING REQUIREMENTS ARE: INSTALL SHEETROCK TO LAUNDRY ROOM CEILING, PROTECT NM CABLES REMOVE THE UNPERMITTED SEWER CONNECTION REMOVE THE REFUSE FROM THE PROPERTY CLEAN INTERIOR. |
|
| 06/01/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | SPOKE TO OFFICER MORKEN HE WAS ON SITE WITH OWNER # T2106010094. INFORM OFFICER OWNER IS ALLOWED ON PROPERTY DURNING DAYLIGHT HOURS FOR REPAIRES ONLY. OFFICER DID REPORT THE UNSAFE TO OCUPPY LABEL HAS BEEN REMOVED FROM STRUCTURE. INFORM OFFICER WILL BE AN INSPECTION TOMORROW WITH INSPECTOR VALDEZ AND VIDAL. | |
| 05/28/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | Check the site for the work with out permits and the wall in the living room has been removed making a room but still has the closet and the wall being blocked off to the kitchen area. The walls making the closet will need to be removed to be back to the orginal layout. Still lacking the smoke detectors in the bedrooms, the wall on the rear porch are still up and will need to be removed and back to a porch. Does have 4 coarse of block at the west side that will need to be removed and the water lines for the hot and cold will need to be removed to the water heater. The sewer drainage line that is connected to the clean-out will need to be removed and capped at the clean-out. The owner is stating about making that area into a kitchen and will need to have the permit approved on what work is going to be done. If that work is going to be done than the citation will stay in place. The owner will remove the walls and the block and will call to check when completed. RV. | |
| 05/28/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | ONSITE MEETING WITH OWNER AND INSPECTOR VIDAL TPD. WORK PLAN TO BE ASSIGNED AND EMAILED |
|
| 05/26/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | WAS CALLED BY TPD DUE TO PROPERTY WAS BREACHED, PERSON WAS ARRESTED AND PROPERTY WAS BOARDED, AND METER WAS PULLED, PANEL PAD LOCKED DUE TO TAMPERING , WILL REFF CASE BACK TO INSPECTOR JUAN VALDEZ. | |
| 05/18/2021 | INSP - FOLLOW UP CODE ENFORCE | Approved | ONSITE: INSPECTION WITH TPD AND OWNER, NO COMPLIANCE WITH THE NOTICE OF VIOLATION PREVIOUSLY ISSUED ON MAY 6, 2021. EGRESS, ELECTRICAL CODE VIOLATIONS, UNSANITARY CONDITIONS IN THE INTERIOR, WORK WITHOUT PERMITS ARE WHAT CAUSING THE EGRESS ISSUES, POWER WAS TURNED OFF AT THE DISCONNECT DUE TO EXTESION CORDS BEING USED AS PERMANENT WIRING, THE LAUNDRY ROOM HAS ALL HOME RUNS WHICH ARE DEFIENED AS ALL INTERIOR WIRING EXPOSED AND NOT PROTECTED, NO OCCUPANCY ALLOWED UNTIL CODE VIOLATIONS ARE ABATED, INSPECTION REQUIRED, VIOLATION OF THESE ORDERS WILL RESULT IN POWER TO BE DISCONNECTED BY TEP AND THE DWELLING SHALL BE FULY BOARDED, THE OWNER OR LICENSED CONTRACTORS MAY WORK ON THE CODE VIOLATIONS DURING DAY TIME ONLY. NO ONE ALLOWED IN THE DWELLING AT NIGHT. POWER SHALL BE TURNED BY CITY INSPECTOR ONLY. THE DWELING SHALL BE SECURED BY THE OWNER TO PREVENT UNAUTHORIZED ENTRY. |