Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T21DV02420
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/24/2021 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CAL OUT BY TFD: THERE IS FIRE DAMAGE TO THE LIVING ROOM AREA, THE 10' X 14' ROOF PLANKING IN THE LIVING ROOM HAS 1/8 INCH ALLIGATORING CRACKS ALONG WITH ONE 4 X 6 RAFTER. THE ENTIRE CEILING AND WALLS HAVE PAINT PEELING. THE HALLWAY, BATHROOM, BEDROOMS AND KITCHEN ALSO HAVE WALLS AND CEILING WITH PAINT PEELING. THE HALLWAY AND LIVING SHEETROCK HAVE DAMAGE TO THE SHEETROCK PAPER. THE LIVING ROOM'S 3 X 4 ENCASEMENT WINDOW HAS BROKEN AN CRACKED PANES AND BROKEN PANE., THE LARGE 5 X 8 PICTURE WINDOW IS BROKEN, THE REAR FRENCH DOOR HAS ONE PANE BROKEN ON ONE OF THE DOORS. THE WALLS AND CEILING IN ABOVE AREAS ARE BLACKED DUE TO HEAVY SMOKE. ELECTRICAL: THE LIVING ROOM AND HALLWAY HAVE ELECTRICAL DEVICES WHICH HAVE MELTED AND SIGNS OF HEAT DAMAGE. TEP DID DISCONNECT POWER. PLUMBING: SWG DID PIN METER OFF MECHANICAL: HEAVY SMOKE TO ENTIRE HOME REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY. DAMAGED OPENINGS SHALL BE SECURED BY THE OWNERS CONTRACTOR WITHIN 12 HOURS. |