Case: T21DV02420

Parcel: 123140440


Addresses:

850 E SENECA ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T21DV02420

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
04/24/2021 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CAL OUT BY TFD: THERE IS FIRE DAMAGE TO THE LIVING ROOM AREA, THE 10' X 14' ROOF PLANKING IN THE LIVING ROOM HAS 1/8 INCH ALLIGATORING CRACKS ALONG WITH ONE 4 X 6 RAFTER. THE ENTIRE CEILING AND WALLS HAVE PAINT PEELING. THE HALLWAY, BATHROOM, BEDROOMS AND KITCHEN ALSO HAVE WALLS AND CEILING WITH PAINT PEELING. THE HALLWAY AND LIVING SHEETROCK HAVE DAMAGE TO THE SHEETROCK PAPER. THE LIVING ROOM'S 3 X 4 ENCASEMENT WINDOW HAS BROKEN AN CRACKED PANES AND BROKEN PANE., THE LARGE 5 X 8 PICTURE WINDOW IS BROKEN, THE REAR FRENCH DOOR HAS ONE PANE BROKEN ON ONE OF THE DOORS. THE WALLS AND CEILING IN ABOVE AREAS ARE BLACKED DUE TO HEAVY SMOKE.


ELECTRICAL: THE LIVING ROOM AND HALLWAY HAVE ELECTRICAL DEVICES WHICH HAVE MELTED AND SIGNS OF HEAT DAMAGE. TEP DID DISCONNECT POWER.


PLUMBING: SWG DID PIN METER OFF


MECHANICAL: HEAVY SMOKE TO ENTIRE HOME

REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY. DAMAGED OPENINGS SHALL BE SECURED BY THE OWNERS CONTRACTOR WITHIN 12 HOURS.