Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T21DV01175

Parcel: 115061690


Addresses:

219 W PLATA ST


Inspection Status: Passed

Inspection History: COT - ENFC - Code Enforcement - Follow Up

Case Number - T21DV01175

Inspection Description - COT - ENFC - Code Enforcement - Follow Up

Inspection Status - Passed

Date Description Inspector Results Comments
09/03/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - MET ONSITE WITH CW ELECTRICAL AND MANAGEMENT DISCUISS CODE REQUIREMENTS WILL CONNECT ON EMAIL Code Violations: VIOLATION: OUTSIDE FEEDERS WHICH RUN OVER MOBILE HOMES DO NOT HAVE PROPER CLEARANCE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE ARTICLE 225 OUTSIDE BRANCH CIRCUIT AND FEEDERS 225.19 CLEARANCES FROM BUILDINGS FOR CONDUCTORS OF NOT OVER 1000 VOLTS, NOMINAL. (A) ABOVE ROOFS. OVERHEAD SPANS OF OPEN CONDUCTORS AND OPEN MULTI-CONDUCTOR CABLES SHALL HAVE A VERTICAL CLEARANCE OF NOT LESS THAN 2.7 M (8 FT 6 IN.) ABOVE THE ROOF SURFACE. THE VERTICAL CLEARANCE ABOVE THE ROOF LEVEL SHALL BE MAINTAINED FOR A DISTANCE NOT LESS THAN 900 MM (3 FT) IN ALL DIRECTIONS FROM THE EDGE OF THE ROOF. Re energize the permit for the emergency repair of the service T21CM07705 Please address the electrical plan review comments and provide a written response. Ref; Electrical Design. 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered Electrical design professional. Provide complete electrical plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. Ref; 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements
08/15/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - OUTSIDE FEEDERS IMPACT 6 MOBILE HOMES ARE AFFECTED, 7, 8,9,10,14 AND 13 REFUSE ON THE GROUNDS IN MULTIPLE SPACES, BUT SPACE 10 WAS CLEANED T21CM07705 was returned for correction, no active VIOLATION: OUTSIDE FEEDERS WHICH RUN OVER MOBILE HOMES DO NOT HAVE PROPER CLEARANCE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE ARTICLE 225 OUTSIDE BRANCH CIRCUIT AND FEEDERS 225.19 CLEARANCES FROM BUILDINGS FOR CONDUCTORS OF NOT OVER 1000 VOLTS, NOMINAL. (A) ABOVE ROOFS. OVERHEAD SPANS OF OPEN CONDUCTORS AND OPEN MULTI-CONDUCTOR CABLES SHALL HAVE A VERTICAL CLEARANCE OF NOT LESS THAN 2.7 M (8 FT 6 IN.) ABOVE THE ROOF SURFACE. THE VERTICAL CLEARANCE ABOVE THE ROOF LEVEL SHALL BE MAINTAINED FOR A DISTANCE NOT LESS THAN 900 MM (3 FT) IN ALL DIRECTIONS FROM THE EDGE OF THE ROOF.
08/16/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - COURT; ALL PARTIES PRESENT ATTORNEY AND CANNON OF THE MANAGEMENT CO. HE STATED THAT THE PROPERTY IS UNDER NEW OWNERSHIP VILLA VISTA MHP TUCSON AZ LLC BUT WILLING TO CONTINUE FORWARD WITH THE REMAINING CODE VIOLATIONS THE JUDGE ASKS THE CITY WHAT ARE THE TOP CONCERNS: PERMITS REQUIRED TO INCREASE OUTDOOR FEEDERS RE-ACTIVE THE PERMIT FOR THE EMERGENCY REPAIR OF THE SERVICE THE JUDGE ALSO ASKED THE PARK OWNERS TO ALERT ALL OCCUPIED UNITS WITH THE LOW HANGING FEEDERS TO NOT GO ON THE ROOF ELECTRIC CONTRACTOR TO MEET WITH INSPECTOR VALDEZ ONSITE THE OWNERSHIP DID STATE THEY AGREE WITH ALL OF THE CONDITIONS
03/11/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - 219 W PLATA 8-25-2021 OUTSIDE FEEDERS ADDRESSED IN A NOTICE OF VIOLATION IN 2018 HAVEN'T BEEN ADDRESSED. 6 MOBILE HOMES ARE AFFECTED, 7, 8,9,10,14 AND 13 8-25-2021 NO CHANGE, OR PERMITS 3-11-2022 NO CHANGE, OR PERMITS 219 W PLATA ST 3-02-2021 ONSITE INSPECTION: FOUND HAZARDOUS ELECTRICAL IN SPACE 13 AND 14 UNAPPROVED WIRING METHODS, EXPOSED AND UNPROTECTED WIRING, CIRCUIT BREAKER RATING EXCEEDS THE WIRE AMPACITY. THE BREAKER WERE SHUT OFF. UNAPPROVED WIRING METHODS TO A WATER HEATER AND UNKNOWN LOCATIONS. THESE HAZARDS WERE ABATED ONSITE BUT CITED REFUSE ON THE GROUNDS IN MULTIPLE SPACES, DILAPIDATED CARPORT WALL IN SPACE 10, 8-25-2021 NO CHANGE 3-11-2022 SPACE 10 HAS DILAPIDATED WALL AND REFUSE. RV'S WERE REMOVED. THE BROKEN WOOD AND SHEETROCK HAS NOT BEENCLEANED FROM SPACE 10.
08/25/2021 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - 219 W PLATA 8-25-2021 OUTSIDE FEEDERS ADDRESSED IN A NOTICE OF VIOLATION IN 2018 HAVEN'T BEEN ADDRESSED. 6 MOBILE HOMES ARE AFFECTED, 7, 8,9,10,14 AND 13 NO 8-25-2021 NO CHANGE, OR PERMITS 219 W PLATA ST 3-02-2021 ONSITE INSPECTION: FOUND HAZARDOUS ELECTRICAL IN SPACE 13 AND 14 UNAPPROVED WIRING METHODS, EXPOSED AND UNPROTECTED WIRING, CIRCUIT BREAKER RATING EXCEEDS THE WIRE AMPACITY. THE BREAKER WERE SHUT OFF. UNAPPROVED WIRING METHODS TO A WATER HEATER AND UNKNOWN LOCATIONS. THESE HAZARDS WERE ABATED ONSITE BUT CITED REFUSE ON THE GROUNDS IN MULTIPLE SPACES, DILAPIDATED CARPORT WALL IN SPACE 10, 8-25-2021 NO CHANGE. 8-25-2021 NO APPROVED SITE PLAN FOR RV USE OR STORAGE IMPROVEMENTS 8-25-2021 UNIT 4 WAS REMOVED UNIT 2 BOARDS REMOVED CURRENTLY VACANT RV NEXT TO UNIT 20 WAS REMOVED 8-25-2021 UNIT 35 VACANT AND BOARDED AND OCCUPIED
04/01/2021 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - ONSITE MEETING WITH PLATA MANAGEMENT
03/25/2021 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - ONSITE FOR PURPOSE OF THE AUDIT TOUR
03/26/2021 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - JUSTICE WEB SUBMITTED FOR TWO CASE WITH DIFFERRENT DATES,