Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 10/18/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
TLUNDBERG |
Approved |
Entered by NGARCIA3 - AP |
| 10/14/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
ESTEVENS |
Partial Approval |
Entered by NGARCIA3 - Partial. DWV PASSED. Pex is to close to the can lighting.
Re-inspection fee applies. $165.00 |
| 10/13/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
SCARRAZCO |
Not ready for Inspection |
Entered by NGARCIA3 - Not ready. Canceled per contractor. |
| 10/12/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
SCARRAZCO |
Not ready for Inspection |
Entered by NGARCIA3 - Not ready. Provide DWV test. |
| 10/11/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
TLUNDBERG |
Cancelled |
Entered by NGARCIA3 - CA per Sean |
| 10/07/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
SCARRAZCO |
Not ready for Inspection |
Entered by RSALDAT1 - Not ready. Per previous notes. Stacks are empty. |
| 10/05/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
SCARRAZCO |
Not ready for Inspection |
Entered by VVERA1 - Not ready plumbing line in downstairs bathroom has a leak. Fitting needs to be glued. |
| 09/26/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
SCARRAZCO |
Not ready for Inspection |
Entered by VVERA1 - not ready. Missing nail plates on vent lines. Provide DWV test through second floor. Provide fire foam at all top penetrations. At stud shoes to over notching studs. |