Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2022 | COT - RSBU - Exterior Clips/Sheathing | TLUNDBERG | Approved | Entered by RSALDAT1 - AP |
02/11/2022 | COT - RSBU - Exterior Clips/Sheathing | TLUNDBERG | Correction Required | Entered by VVERA1 - CO 1. Opening at patio door calls for 3 king studs each end. 2. Connection from truss to shear wall not per detail 14/SD1.3c condition A |