Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSPL - Plumbing Final
Permit Number - T21CM09571
Inspection Description - COT - RSPL - Plumbing Final
Inspection Status - Canceled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/07/2022 | COT - RSPL - Plumbing Final | Canceled | Inspection Canceled | |
12/23/2021 | COT - RSPL - Plumbing Final | DQUINN | Denied | Entered by NGARCIA3 - de TPR drain must terminate in the pan. These drains can no longer be be run in an upward direction in a landlocked situation with no access to an exterior wall. Also, a carbon monoxide tester must be installed at an appropriate location in the home. See installation specs. |