Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: RESIDENTIAL INTERMEDIATE
Permit Number - T21CM09468
Inspection Description - RESIDENTIAL INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2022 | RESIDENTIAL INTERMEDIATE | Approved | AP | |
06/02/2022 | RESIDENTIAL INTERMEDIATE | Correction Required | https://www.arcgis.com/apps/workforce/projects/a5a1af8158fc4692b846e1ea3becd303/dispatch/assignments/126665#:~:text=CO%0A1.%20Flush%20blocking%20at%20garage%20sheer%20wall.%0A2.%20Incorrect%20nail%20plates%20over%20PEX/ABS%20in%20kitchen%20wall%0A3.%20Nail%20plate%20romex%20under%20stair%0A4.%20Block%20register%20at%20front%20door%0A5.%20Block%20base%20of%20stair%20landing%0A6.%20Provide%20City%20Approved%20plumbing/soil%20isometric | |
05/31/2022 | RESIDENTIAL INTERMEDIATE | Not ready for Inspection | NR Cancel all other inspections |
|
05/20/2022 | RESIDENTIAL INTERMEDIATE | Correction Required | corrections required, Hatdwire all exhaust fans, install fan box @ back patio & bedrooms. Install missing electrical boxes and secure 4 gang boxes. | |
05/17/2022 | RESIDENTIAL INTERMEDIATE | Correction Required | CO 1. Support 4-gang box at both ends 2. Vents are dry 3. Block registers 4. Fire block top & bottom of both AC chases 5. Over notched 2x6 studs at 2nd floor |
|
05/13/2022 | RESIDENTIAL INTERMEDIATE | Cancelled | IVRS - RI canceled | |
05/11/2022 | RESIDENTIAL INTERMEDIATE | Cancelled | Cancel all inspections per Shane |