Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 07/29/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
TLUNDBERG |
Approved |
Entered by NGARCIA3 - AP |
| 07/27/2022 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
TLUNDBERG |
Denied |
Entered by VVERA1 - DE
1. Incorrect lags used in stud shoes, incorrect size of stud shoe
2. Gas pressure test fail
3. Anchor bolts required within 12” of end of plate
4. Block under staid landing at floor joint
5. Insulate behind tub
6.maintain 10’ clearance between vent and fresh air intake
7. Repair abandoned fresh air hole in roof |