Permit: T21CM08140

Parcel: 118062830

Inspection Status: Not Ready

Inspection History: COT - LCPL - Plumbing Intermediate 

Permit Number - T21CM08140

Inspection Description - COT - LCPL - Plumbing Intermediate 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - LCPL - Plumbing Intermediate  Not Ready
03/17/2023 COT - LCPL - Plumbing Intermediate  Not Ready Unit 2. Not ready. Space pex line from any can lights minimum 12”. Provide DWV test. Missing receptacle in second bedroom. Fire foam all top penetrations. Add nail plates to any lint that’s less than an 1” 1/4. 3/17/2023
03/23/2023 COT - LCPL - Plumbing Intermediate  Passed 3/23/2023 approved. Corrections were made.