Permit: T21CM08091

Parcel: 12407064A


Addresses:

738 E 9TH ST 01


Inspection Status: Canceled

Inspection History: COT - RSEL - Electrical Final 

Permit Number - T21CM08091

Inspection Description - COT - RSEL - Electrical Final 

Inspection Status - Canceled

Date Description Inspector Results Comments
11/04/2022 COT - RSEL - Electrical Final  Canceled Inspection Canceled
10/24/2025 COT - RSEL - Electrical Final  Re-inspection required 10.24.25
Unit 1
Kitchen receptacles must be GFCI, minimum 2 separate circuits
Water hammer arresters missing at dishwasher and washer box
Bathroom GFCI non functional
Mini split requires emission report to show that it is equal to or greater than US standard
Outdoor receptacles must be WR Weather resistant and GFCI
Labeling missing at panel schedule, open slots must be filled/covered (both panels)

Unit 2
Mini split and ac unit require emissions test
Water hammer arresters missing throughout
Cover all receptacles
GFCI required at kitchen, 2 circuits minimum
12/01/2025 COT - RSEL - Electrical Final  Passed