Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2021 | EXT METAL CLIPS/EXT SHEATHING | Approved | . AP ALL CORRECTIONS ARE COMPLETE |
|
| 10/22/2021 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | corrections required, Install H25 clips at all bearing points, install hangers @ truss to girder connections per engineer truss calcs, & install gable end bracing where required. Install missing anchor bolts @ sill plates. |