Permit: T21CM07543

Parcel: 111065230


Addresses:

3333 E GLENN ST


Inspection Status: Not Ready

Inspection History: COT - RSEL - Electrical Final 

Permit Number - T21CM07543

Inspection Description - COT - RSEL - Electrical Final 

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - RSEL - Electrical Final  Not Ready
05/22/2023 COT - RSEL - Electrical Final  Canceled Canceled per contractor. 5/22/2023
06/20/2023 COT - RSEL - Electrical Final  Not Ready 6-20-23: No access for inspection.
07/10/2023 COT - RSEL - Electrical Final  Re-inspection required 6-20-23: No access for inspection.
7/10/23: label all breakers area specific, arc-fault smoke det circuit, more breakers may need arc-fault after they are labeled, install UV resistant tape over lineset insulation, install spinners on AC Freon ports, incorrect fuse at AC, all exterior outlets require to be WR, C/O covers missing thruout, UV resistant tape over water service pipe, missing 2 kitchen countertop outlets. Cannot be more than 24" from an outlet, missing handrails at stairs, provide identification for garage air handler to correctly size fuses. THIS INSPECTION WAS STOPPED. MORE ITEMS MAYBE ADDED AT NEXT INSPECTION.
08/15/2023 COT - RSEL - Electrical Final  Not Ready
10/04/2023 COT - RSEL - Electrical Final  Canceled 10/4/23: inspection cancelled by contractor.
12/08/2023 COT - RSEL - Electrical Final  Passed 12/8/23: Electrical panel has been properly labeled, U/V tape has been installed on line set for A/C Unit, spinners have been installed on Freon ports of A/C unit, waterproof covers have been installed on all exterior outlets, proper fuses for A/C unit and air handler have been installed, 2 new outlets were added at kitchen counter, handrails for stairs have been installed, U/V tape has been installed on exterior water line, and anti-siphon devices have been installed on all exterior hose bibs.