Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: RSBU - Building Final
Permit Number - T21CM07543
Inspection Description - RSBU - Building Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | RSBU - Building Final | Not Ready | ||
06/20/2023 | RSBU - Building Final | Not Ready | 6-20-23: No access for inspection. | |
07/10/2023 | RSBU - Building Final | Re-inspection required | 6-20-23: No access for inspection. 7/10/23: label all breakers area specific, arc-fault smoke det circuit, more breakers may need arc-fault after they are labeled, install UV resistant tape over lineset insulation, install spinners on AC Freon ports, incorrect fuse at AC, all exterior outlets require to be WR, C/O covers missing thruout, UV resistant tape over water service pipe, missing 2 kitchen countertop outlets. Cannot be more than 24" from an outlet, missing handrails at stairs, provide identification for garage air handler to correctly size fuses. THIS INSPECTION WAS STOPPED. MORE ITEMS MAYBE ADDED AT NEXT INSPECTION. |
|
08/15/2023 | RSBU - Building Final | Not Ready | ||
10/04/2023 | RSBU - Building Final | Canceled | 10/4/23: inspection cancelled by contractor. | |
12/08/2023 | RSBU - Building Final | Passed | 12/8/23: Electrical panel has been properly labeled, U/V tape has been installed on line set for A/C Unit, spinners have been installed on Freon ports of A/C unit, waterproof covers have been installed on all exterior outlets, proper fuses for A/C unit and air handler have been installed, 2 new outlets were added at kitchen counter, handrails for stairs have been installed, U/V tape has been installed on exterior water line, and anti-siphon devices have been installed on all exterior hose bibs. |